產(chǎn)品詳情
批發(fā)KG AUTO開關(guān)KGT-N2M1V2Y怎么樣氣缸KCM-R-CC-30-250DAEYEON轉(zhuǎn)換器;DY-ADD-3AAC DY-ADD-3BAC DY-ADD-3CAC DY-ADD-3DAC DY-ADD-3OAC
DAEYEON轉(zhuǎn)換器;DY-ADD-31NC DY-ADD-3CNC DY-ADD-33NC DY-ADD-34NC DY-ADD-35NC DY-ADD-36NC
DAEYEON轉(zhuǎn)換器;DY-ADD-3ANC DY-ADD-3BNC DY-ADD-3CNC DY-ADD-3DNC DY-ADD-3ONC
DAEYEON轉(zhuǎn)換器;DY-ADD-31AO DY-ADD-3CAO DY-ADD-33AO DY-ADD-34AO DY-ADD-35AO DY-ADD-36AO
DAEYEON轉(zhuǎn)換器;DY-ADD-3AAO DY-ADD-3BAO DY-ADD-3CAO DY-ADD-3DAO DY-ADD-3OAO
DAEYEON轉(zhuǎn)換器;DY-ADD-31NO DY-ADD-3CNO DY-ADD-33NO DY-ADD-34NO DY-ADD-35NO DY-ADD-36NO
DAEYEON轉(zhuǎn)換器;DY-ADD-3ANO DY-ADD-3BNO DY-ADD-3CNO DY-ADD-3DNO DY-ADD-3ONO
DAEYEON轉(zhuǎn)換器;DY-ADD-31AN DY-ADD-3CAN DY-ADD-33AN DY-ADD-34AN DY-ADD-35AN DY-ADD-36AN
DAEYEON轉(zhuǎn)換器;DY-ADD-3AAN DY-ADD-3BAN DY-ADD-3CAN DY-ADD-3DAN DY-ADD-3OAN
DAEYEON轉(zhuǎn)換器;DY-ADD-31NN DY-ADD-3CNN DY-ADD-33NN DY-ADD-34NN DY-ADD-35NN DY-ADD-36NN
DAEYEON轉(zhuǎn)換器;DY-ADD-3ANN DY-ADD-3BNN DY-ADD-3CNN DY-ADD-3DNN DY-ADD-3ONN
DAEYEON轉(zhuǎn)換器;DY-ADD-41AA DY-ADD-4CAA DY-ADD-43AA DY-ADD-44AA DY-ADD-45AA DY-ADD-46AA
DAEYEON轉(zhuǎn)換器;DY-ADD-4AAA DY-ADD-4BAA DY-ADD-4CAA DY-ADD-4DAA DY-ADD-4OAA

二次側(cè)額定電流通常為1A或5A。其中2×a/C表示同一臺產(chǎn)品有兩種電流比,通過改變產(chǎn)品的連接片接線實現(xiàn),當串聯(lián)時,電流比為a/c,并聯(lián)時電流比為2×a/C。一般情況下,計量用電流互感器變流比的選擇應(yīng)使其一次額定電流I1n不小于線路中的負荷電流(即計算IC)。如線路中負荷計算電流為350A,則電流互感器的變流比應(yīng)選擇400/5。保護用的電流互感器為保證其準確度要求,可以將變比選得大一些。準確級應(yīng)根據(jù)測量準確度[8]要求選擇電流互感器的準確級并進行校驗。下表為不同準確級電流互感器的誤差限值:電流互感器準確級和誤差限值電流互感器準確級和誤差限值準確級選擇的原則:計費計量用的電流互感器其準確級不低于0.5級;此外回路損耗也使諧振過電壓受到阻尼和。當回路電阻大于一定的數(shù)值時,就不會出現(xiàn)強烈的鐵磁諧振過電壓。3)串聯(lián)諧振電路來說,產(chǎn)生鐵磁諧振過電壓的的必要條件是ω01/L0C;因此鐵磁諧振可在很大的范圍內(nèi)發(fā)生。4)維持諧振振蕩和抵償回路電阻損耗的能量均由工頻電源供給。為使工頻能量轉(zhuǎn)化為其它諧振的能量,其轉(zhuǎn)化必須是周期性且有節(jié)律的,即…1/2(1,3…)倍的諧振。5)鐵磁諧振對PT的損壞。電磁諧振(分頻)一般應(yīng)具備如下三個條件。①鐵磁式電壓互感器(PT)的非線性效應(yīng)是產(chǎn)生鐵磁諧振的主要原因。②PT感抗為容抗的100倍以內(nèi),即參數(shù)匹配在諧振范圍。③要有激發(fā)條件,如PT突然合閘、單相接地突然消失、外界對的或操作產(chǎn)生的過電壓等。
是由在滑塊跟導(dǎo)軌之間無限循環(huán),從而使負載平臺沿著導(dǎo)軌輕易的高精度線性運動,并將系數(shù)降至平常導(dǎo)引的五十分之一,能輕易地達到很高的定位精度。滑塊跟導(dǎo)軌間末制單元設(shè)計,使線形導(dǎo)軌同時承受上下左右等各方向的負荷,的回流及精簡化的結(jié)構(gòu)設(shè)計讓HIWIN的線性導(dǎo)軌有更平順且低噪音的運動。滑塊-使運動由曲線轉(zhuǎn)變?yōu)橹本€。新的導(dǎo)軌使機床可快速進給速度,在主軸轉(zhuǎn)速相同的情況下,快速進給是直線導(dǎo)軌的特點。直線導(dǎo)軌與平面導(dǎo)軌一樣,有兩個基本元件;一個作為導(dǎo)向的為固定元件,另一個是元件。由于直線導(dǎo)軌是部件,對機床制造廠來說.要做的只是加工一個安裝導(dǎo)軌的平面和校調(diào)導(dǎo)軌的平行度。當然。
DAEYEON轉(zhuǎn)換器;DY-ADD-41NA DY-ADD-4CNA DY-ADD-43NA DY-ADD-44NA DY-ADD-45NA DY-ADD-46NA
DAEYEON轉(zhuǎn)換器;DY-ADD-4ANA DY-ADD-4BNA DY-ADD-4CNA DY-ADD-4DNA DY-ADD-4ONA
DAEYEON轉(zhuǎn)換器;DY-ADD-41AB DY-ADD-4CAB DY-ADD-43AB DY-ADD-44AB DY-ADD-45AB DY-ADD-46AB
DAEYEON轉(zhuǎn)換器;DY-ADD-4AAB DY-ADD-4BAB DY-ADD-4CAB DY-ADD-4DAB DY-ADD-4OAB
DAEYEON轉(zhuǎn)換器;DY-ADD-41NB DY-ADD-4CNB DY-ADD-43NB DY-ADD-44NB DY-ADD-45NB DY-ADD-46NB
DAEYEON轉(zhuǎn)換器;DY-ADD-4ANB DY-ADD-4BNB DY-ADD-4CNB DY-ADD-4DNB DY-ADD-4ONB
DAEYEON轉(zhuǎn)換器;DY-ADD-41AC DY-ADD-4CAC DY-ADD-43AC DY-ADD-44AC DY-ADD-45AC DY-ADD-46AC
DAEYEON轉(zhuǎn)換器;DY-ADD-4AAC DY-ADD-4BAC DY-ADD-4CAC DY-ADD-4DAC DY-ADD-4OAC
DAEYEON轉(zhuǎn)換器;DY-ADD-41NC DY-ADD-4CNC DY-ADD-43NC DY-ADD-44NC DY-ADD-45NC DY-ADD-46NC
DAEYEON轉(zhuǎn)換器;DY-ADD-4ANC DY-ADD-4BNC DY-ADD-4CNC DY-ADD-4DNC DY-ADD-4ONC
DAEYEON轉(zhuǎn)換器;DY-ADD-41AO DY-ADD-4CAO DY-ADD-43AO DY-ADD-44AO DY-ADD-45AO DY-ADD-46AO
DAEYEON轉(zhuǎn)換器;DY-ADD-4AAO DY-ADD-4BAO DY-ADD-4CAO DY-ADD-4DAO DY-ADD-4OAO

用于各進出線回路中負荷電流大小的電流表應(yīng)選用1.0—3.0級電流互感器。為了保證準確度誤差不超過規(guī)定值,一般還校驗電流互感器二次負荷(伏安),互感器二次負荷S2不大于額定負荷S2n,所選準確度才能保證。準確度校驗公式:S2≤S2n。二次回路的負荷l:取決于二次回路的阻抗Z2的值,則:S2I2n2︱Z2︱≈I2n2(∑︱Zi︱+RWl+RXC)或S2V1≈∑Si+I2n2(RWl+RXC)式中,Si、Zi為二次回路中的儀表、繼電器線圈的額定負荷和阻抗,RXC為二次回路中所有接頭、觸點的電阻,一般取0.1Ω,RWL為二次回路導(dǎo)線電阻,計算公式化為:RWLLC/(r×S)。式中,r為導(dǎo)線的導(dǎo)電率。不允許有嚴重的霉菌存在。技術(shù)指標編輯編輯額定值:50Hz交流5A,波形畸變不超過2%。過流整定范圍為2-9.9A(無輔助電源),級差為0.1A,電流整定值誤差不大于±3%。速動倍數(shù)整定范圍為2-9.9倍,級差為0.1倍,電流速動整定值誤差不大于±3%。繼電器的速動電流用電流整定值的倍數(shù)表示:速動電流速動倍數(shù)×整定電流。速動時間:繼電器任一整定點上,在1.2倍速動電流時的時間不大于50ms。返回系數(shù):不小于0.9。反時限特性曲線方程:t:反時限時間K:延時曲線系數(shù)(整定范圍0.1~9.9)Is:整定電流值I:實際輸入電流值(注:I/Is不大于1.2為不推薦使用段)反時限特性時間整定誤差:a)當I/Is2時,平均誤差不大于10%;

(2)V/V接線是將兩臺全絕緣單相電壓互感器的高低壓繞組分別接于相與相之間構(gòu)成不完全三角形。這種常用于中性點不接地或經(jīng)消弧線圈接地的35kV及以下的高壓三相中,特別是10kV的三相中。(3)用三臺單相三繞組電壓互感器構(gòu)成YN,yn,d0或YN,d0的接線形式,廣泛應(yīng)用于3~220KV中,其二次繞組用于測量相間電壓和相對地電壓,輔助二次繞組接成開口三角形,供接入交流電網(wǎng)絕緣儀表和繼電器用。用一臺三相五柱式電壓互感器代替上述三個單相三繞組電壓互感器構(gòu)成的接線,除鐵芯外,其形式與圖3基本相同,一般只用于3~15KV。(4)三相三繞組五柱式電壓互感器,其一次繞組和主二次繞組接成星形。



